The hollow rotary platform reducer is a revolutionary product. For a variety of rotating motion occasions. So what are the faults of the hollow rotary platform reducer?
> Fault 1: The sound of the hollow rotating platform reducer is abnormal or there is noise:
Reason: lubricating oil impurities more; The gear meshing part is damaged, the gear clearance increases, and the bearing clearance is large; The bearing is badly damaged or worn.
Troubleshooting method: Check the meshing parts, may need to replace the damaged parts. Adjust bearing clearance. Replace damaged bearings.
Fault 2: Bearing temperature is too high:
Reason: the oil level in the hollow rotary platform reducer is too low; Too little lubricating oil, lubricating oil has aging; The bearing is damaged.
Elimination method: Check the oil level at room temperature, may need to add lubricating oil. Check when the oil was last changed and you may need to change the lubricant. Check bearing, may need to be replaced.
Fault 3: The working temperature of the hollow rotating platform reducer is high:
Reason: the oil level in the reducer is too high or the amount of oil is less, the oil has been aging, and the lubricating oil is seriously polluted.
Troubleshooting method: Check the oil level, may need to correct the oil level. Check when the oil was last changed and you may need to change the oil.
Fault 4: Tooth surface wear or corrosion of hollow rotary platform reducer:
Reason: lubricating oil quality is not qualified or contains impurities.
Elimination method: replace the worn gear and change the lubricating oil.
Fault 5: Hollow shaft rotating platform gear tooth fracture:
Reason: overload work, gear quality problems.
Elimination method: Replace the parts, recalculate the load to see if the selection is correct.
Fault 6: Input shaft fracture:
Reason: the radial force is too large, the coupling installation error is too large, quality problems.
Elimination method: Replace parts. When the user uses the pulley to input power, check whether the radial force exceeds the specified maximum. Check whether the coupling installation Angle error is out of tolerance.
Fault 7: Hollow shaft rotating platform reducer box cracking:
Reason: radial force is too large, tooth fracture, quality problems.
Elimination method: When the user uses the chain drive to output power, it is very necessary to check the radial force, such as the radial force exceeds the specified maximum value, it is recommended that the user use a welded box or a larger model.
Fault 8: Oil seal seepage, oil leakage:
Reason: The oil seal is faulty.
Elimination method: Replace the oil seal. Check the oil seal shaft for wear and may need to be replaced.
How much do you know about the failure of hollow rotary platform reducer and its causes?
2024-04-24RV reducer VS Harmonic reducer, which performance is better?
2024-04-18Desen transmission 2023 Shanghai Expo came to a perfect end
2024-04-18How to improve the gear quality of gear reducer?
2024-04-08The location selection and fixing of the reducer is very important
2024-04-08301,Building 2, No. 3 Gongye Avenue, Beijiao Town, Shunde District, Foshan, China
Copyright © 2023 DINSENSE TRANSMISSION EQUIPMENT CO., LIMITED
Site by Ceall.net.cn